Marine Generator M673LD3: 5/4.5 kW
Engine Block
• Four cycle, 3 cylinder, liquid cooled, naturally aspirated, overhead valve diesel.
• Swirl combustion chambers improve fuel efficiency and reduce smoke.
• Glow plugs for quick cold starting.
Cooling System
• Freshwater cooling.
• Heat exchanger or keel cooled.
• One-piece heat exchanger, expansion tank and liquid cooled exhaust manifold. Fewer troublesome hoses and gaskets. Cast iron to resist corrosion and electrolysis.
• Heat exchanger cooling is standard. Cupro-nickel, tube-type heat exchanger has removable ends for easy cleaning. Rubber impeller, seawater pump of bronze and stainless steel is gear driven; no belt.
Fuel System
• Fuel system is self-venting.
• Injection pump with 5% mechanical governor for close AC frequency control.
• Pintle injectors with replaceable tips.
• Mechanical lift pump with hand primer. No electric pump to fail.
• Large spin-on fuel filter.
• Flexible fuel lines routed to fuel manifold.
• Stop solenoid acts directly on the fuel rack eliminating linkage problems.
Intake and Exhaust
• Meets US EPA Tier III emission standards at date of manufacture.
• Washable air cleaner.
• Cast aluminum intake manifold with Sound Maze air intake reduces intake noise.
• Cast iron, wet exhaust elbow for safety.
Lubrication System
• Full flow, spin-on oil filter with bypass.
• 3.1 qt (3 ltr) oil capacity for better lubrication and 200 hour oil change intervals.
• Oil drain for quick, clean oil changes.
• Closed crankcase vent system traps oil vapor and keeps engine room clean.
DC Electrical System
• DC system uses reliable relays instead of an unrepairable printed circuit board.
• 12 volt starter motor and battery charging alternator with belt guard.
• Standard panel: Remote mount S-1B has hour meter, stop-start switch with run light and preheat switch.
• Expandable to six panels up to 110 feet from the set.
• 20 foot (6m) plug-in panel harness lets you mount your panel anywhere onboard. Better than inaccessible unit mount panels that are prone to vibration problems.
• Low oil pressure, high coolant temp and high exhaust temp safety shutdowns standard.
AC Generator
• Northern Lights, direct coupled, four pole, revolving field, four lead reconnectable generator with Class “H” insulation and prelubricated bearing. Conservative heat rise rating: 95°C/50°C ambient .
• External automatic voltage regulator gives you ±5% voltage regulation. AVR powered by dedicated AC winding for improved motor starting. AVR circuit breaker.
• 30 amp mainline circuit breaker protects
Marine Generator M673L3: 6/5 kW
Engine Block
• Four cycle, 3 cylinder, liquid cooled, naturally aspirated, overhead valve diesel.
• Swirl combustion chambers improve fuel efficiency and reduce smoke.
• Glow plugs for quick cold starting.
Cooling System
• Freshwater cooling with siphon break.
• Heat exchanger or keel cooled.
• One-piece heat exchanger, expansion tank and liquid cooled exhaust manifold. Fewer troublesome hoses and gaskets. Cast iron to resist corrosion and electrolysis.
• Heat exchanger cooling is standard. Cupro-nickel, tube-type heat exchanger has removable ends for easy cleaning. Rubber impeller seawater pump of bronze and stainless steel is gear driven; no belt.
Fuel System
• Fuel system is self-venting.
• Injection pump with 5% mechanical governor for close AC frequency control.
• Pintle injectors with replaceable tips.
• Mechanical lift pump with hand primer. No electric pump to fail.
• Large spin-on fuel filter.
• Steel fuel lines.
• Stop solenoid acts directly on the fuel rack eliminating linkage problems.
Intake and Exhaust
• Meets US EPA Tier III emission standards.
• Washable air cleaner.
• Cast aluminum intake manifold with Sound Maze air intake reduces intake noise.
• Cast iron, wet exhaust elbow for safety.
Lubrication System
• Full flow, spin-on oil filter with bypass.
• 3.1 qt (3 ltr) oil capacity for better lubrication and 200 hour oil change intervals.
• Oil drain for quick, clean oil changes.
• Closed crankcase vent system traps oil vapor and keeps engine room clean.
DC Electrical System
• DC system uses reliable relays instead of an unrepairable printed circuit board.
• 12 volt starter motor and battery charging alternator with regulator and belt guard.
• Standard panel: Remote mount S-1B has hour meter, stop-start switch with run light and preheat switch.
• Expandable to six panels up to 110 feet from the set.
• 20 foot (6m) plug-in panel harness lets you mount your panel anywhere onboard. Better than inaccessible unit mount panels that are prone to vibration problems.
• Low oil pressure, high coolant temp and high exhaust temp safety shutdowns standard.
AC Generator
• Northern Lights, direct coupled, four pole, revolving field, four lead reconnectable generator with Class “H” insulation and prelubricated bearing. Conservative heat rise rating: 95°C/50°C ambient .
• External automatic voltage regulator gives you ±5% voltage regulation. AVR powered by dedicated AC winding for improved motor starting. AVR circuit breaker.
Marine Generator M773LW3: 9/7 kW
Engine Block
• Four cycle, 3 cylinder, liquid cooled, naturally aspirated, overhead valve diesel.
• Swirl combustion chambers improve fuel efficiency and reduce smoke.
• Glow plugs for quick cold starting.
Cooling System
• Freshwater cooling system in heat exchanger or keel cooled configuration.
• One-piece heat exchanger, expansion tank and liquid cooled exhaust manifold. Fewer troublesome hoses and gaskets. Cast iron to resist corrosion and electrolysis.
• Heat exchanger cooling is standard. Cupro-nickel, tube-type heat exchanger has removable ends for easy cleaning. Rubber impeller seawater pump of bronze and stainless steel is gear driven; no belt.
Fuel System
• Fuel system is self-venting.
• Injection pump with 5% mechanical governor for close AC frequency control.
• Pintle injectors with replaceable tips.
• Mechanical lift pump with hand primer. No electric pump to fail.
• Large spin-on fuel filter.
• Flexible fuel lines routed to fuel manifold.
• Stop solenoid controls the fuel rack, not the throttle, to eliminate speed variances and linkage problems.
Intake and Exhaust
• Meets US EPA Tier III emission standards at date of manufacture.
• Washable air cleaner in cast intake manifold reduces noise.
• Cast iron, wet exhaust elbow for safety.
Lubrication System
• Full flow, spin-on oil filter with bypass.
• 4.2 qt (4 ltr) oil capacity for better lubrication. 200 hour oil change intervals.
• Oil drain for quick, clean oil changes.
• Closed crankcase vent system traps oil vapor and keeps engine room clean.
DC Electrical System
• DC system uses reliable relays instead of an unrepairable printed circuit board.
• 12 volt starter motor and battery charging alternator with regulator and belt guard.
• Standard panel: Remote mount S-1B has hour meter, stop-start switch with run light and preheat switch.
• Expandable to six panels up to 110 feet from the set.
• 20 foot (6m) plug-in panel harness lets you mount your panel anywhere onboard. Better than inaccessible unit mount panels that are prone to vibration problems.
• Low oil pressure, high coolant temp and high exhaust temp safety shutdowns standard.
AC Generator
• Northern Lights, direct coupled, brushless AC generator is maintenance free. 4 lead, 1 phase, 50 or 60 Hz output standard. 12 lead, 3 phase optional. Conservative heat rise rating: 95oC/50oC ambient.
• Automatic voltage regulator (AVR) is powered by dedicated AC winding for true 300% short circuit capability and circuit breaker protection. Quick ±1% RMS no load to full load voltage regulation.
• Generator features high quality, Class “H” epoxy insulation, accessible diodes, over-sized bearings and junction box for wiring.
Special Equipment
• Welded steel base frame with drip pan.
• Four plateform mounts isolate vibration.
• White, long-life polyurethane paint.
• Operator’s and parts manuals standard.
Classification Standards
• Consult factory for details.
Marine Generator-M843NW3-12/10 kW.
Engine Block
• Four cycle, 3 cylinder, liquid cooled, naturally aspirated, overhead valve diesel.
• Swirl combustion chambers improve fuel efficiency and reduce smoke.
• Glow plugs for quick cold starting.
Cooling System
• Freshwater cooling system in heat exchanger or keel cooled configuration.
• One-piece heat exchanger, expansion tank and liquid cooled exhaust manifold. Fewer troublesome hoses and gaskets. Cast iron to resist corrosion and electrolysis.
• Heat exchanger cooling is standard. Cupro-nickel tube-type heat exchanger has removable ends for easy cleaning. Rubber impeller seawater pump of bronze and stainless steel is gear driven; no belt.
Fuel System
• Fuel system is self-venting.
• Injection pump with 5% mechanical governor for close AC frequency control.
• Pintle injectors with replaceable tips.
• Mechanical lift pump with hand primer. No electric pump to fail.
• Large spin-on fuel filter.
• Flexible fuel lines routed to fuel manifold.
• Stop solenoid controls the fuel rack, not the throttle, to eliminate speed variances and linkage problems.
Intake and Exhaust
• Meets US EPA Tier III emission standards at date of manufacture.
• Washable air cleaner in cast intake manifold reduces intake noise.
• Cast iron, wet exhaust elbow for safety.
Lubrication System
• Full flow, spin-on oil filter with bypass.
• 4.2 qt (4 ltr) oil capacity for better lubrication. 200 hour oil change intervals.
• Oil drain for quick, clean oil changes.
• Closed crankcase vent system traps oil vapor and keeps engine room clean.
DC Electrical System
• DC system uses reliable relays instead of an unrepairable printed circuit board.
• 12 volt starter motor and battery charging alternator with regulator and belt guard.
• Standard panel: Remote mount S-1B has hour meter, stop-start switch with run light and preheat switch.
• Expandable to six panels up to 110 feet from the set.
• 20 foot (6m) plug-in panel harness lets you mount your panel anywhere onboard. Better than inaccessible unit mount panels that are prone to vibration problems.
• Low oil pressure, high coolant temp and high exhaust temp safety shutdowns standard.
AC Generator
• Northern Lights, direct coupled, brushless AC generator is maintence free. 4 lead, 1 phase, 50 or 60 Hz output standard. 12 lead, 3 phase optional. Conservative heat rise rating: 95oC/50oC ambient.
• Automatic voltage regulator (AVR) is powered by dedicated AC winding for true 300% short circuit capability and circuit breaker protection. Quick ±1% RMS no load to full load voltage regulation.
• Generator features high quality, Class “H” epoxy insulation, accessible diodes, over-sized bearings and junction box for wiring.
Special Equipment
• Welded steel base frame with drip pan.
• Four plateform mounts isolate vibration.
• White, long-life polyurethane paint.
• Operator’s and parts manuals standard.
Classification Standards
• Consult factory for details.
Marine Generator M844DW3:16/14 Kw
Engine Block
• Four cycle, 4 cylinder, liquid cooled, naturally aspirated, overhead valve diesel.
• Swirl combustion chambers improve fuel efficiency and reduce smoke.
• Glow plugs for quick cold starting.
Cooling System
• Freshwater cooling system in heat exchanger or keel cooled configuration.
• One-piece heat exchanger, expansion tank and liquid cooled exhaust manifold. Fewer troublesome hoses and gaskets. Cast iron to resist corrosion and electrolysis.
• Heat exchanger cooling is standard. Cupro-nickel tube-type heat exchanger has removable ends for easy cleaning. Rubber impeller seawater pump of bronze and stainless steel is gear driven; no belt.
Fuel System
• Fuel system is self-venting.
• Injection pump with 5% mechanical governor for close AC frequency control.
• Pintle injectors with replaceable tips.
• Mechanical lift pump with hand primer. No electric pump to fail.
• Large spin-on fuel filter.
• Flexible fuel lines routed to fuel manifold.
• Stop solenoid controls the fuel rack, not the throttle, to eliminate speed variances and linkage problems.
Intake and Exhaust
• Meets US EPA Tier III emission standards at date of manufacture.
• Washable air cleaner in cast intake manifold reduces intake noise.
• Cast iron, wet exhaust elbow for safety.
Lubrication System
• Full flow, spin-on oil filter with bypass.
• 8.6 qt (8.2 ltr) oil capacity for better lubrication. 200 hour oil change intervals.
• Oil drain for quick, clean oil changes.
• Closed crankcase vent system traps oil vapor and keeps engine room clean.
DC Electrical System
• DC system uses reliable relays instead of an unrepairable printed circuit board.
• 12 volt starter motor and battery charging alternator with regulator and belt guard.
• Standard panel: Remote mount S-1B has hour meter, stop-start switch with run light and preheat switch.
• Expandable to six panels up to 110 feet from the set.
• 20 foot (6m) plug-in panel harness lets you mount your panel anywhere onboard. Better than inaccessible unit mount panels that are prone to vibration problems.
• Low oil pressure, high coolant temp and high exhaust temp safety shutdowns standard.
AC Generator
• Northern Lights, direct coupled, brushless AC generator is maintence free. 4 lead, 1 phase, 50 or 60 Hz output standard. 12 lead, 3 phase optional. Conservative heat rise rating: 95oC/50oC ambient.
• Automatic voltage regulator (AVR) is powered by dedicated AC winding for true 300% short circuit capability and circuit breaker protection. Quick ±1% RMS no load to full load voltage regulation.
• Generator features high quality, Class “H” epoxy insulation, accessible diodes, over-sized bearings and junction box for wiring.
Special Equipment
• Welded steel base frame with drip pan.
• Four plateform mounts isolate vibration.
• White, long-life polyurethane paint.
• Operator’s and parts manuals standard.
Classification Standards
• Consult factory for details.
Marine Generator M844LW3: 20/16 Kw
Engine Block
• Four cycle, 4 cylinder, liquid cooled, naturally aspirated, overhead valve diesel.
• Swirl combustion chambers improve fuel efficiency and reduce smoke.
• Glow plugs for quick cold starting.
Cooling System
• Freshwater cooling system in heat exchanger or keel cooled configuration.
• One-piece heat exchanger, expansion tank and liquid cooled exhaust manifold. Fewer troublesome hoses and gaskets. Cast iron to resist corrosion and electrolysis.
• Heat exchanger cooling is standard. Cupro-nickel tube-type heat exchanger has removable ends for easy cleaning. Rubber impeller seawater pump of bronze and stainless steel is gear driven; no belt.
Fuel System
• Fuel system is self-venting.
• Injection pump with 5% mechanical governor for close AC frequency control.
• Pintle injectors with replaceable tips.
• Mechanical lift pump with hand primer. No electric pump to fail.
• Large spin-on fuel filter.
• Flexible fuel lines routed to fuel manifold.
• Stop solenoid controls the fuel rack, not the throttle, to eliminate speed variances and linkage problems.
Intake and Exhaust
• Meets US EPA Tier III emission standards at date of manufacture.
• Washable air cleaner in cast intake manifold reduces intake noise.
• Cast iron, wet exhaust elbow for safety.
Lubrication System
• Full flow, spin-on oil filter with bypass.
• 8.6 qt (8.2 ltr) oil capacity for better lubrication. 200 hour oil change intervals.
• Oil drain for quick, clean oil changes.
• Closed crankcase vent system traps oil vapor and keeps engine room clean.
DC Electrical System
• DC system uses reliable relays instead of an unrepairable printed circuit board.
• 12 volt starter motor and battery charging alternator with regulator and belt guard.
• Standard panel: Remote mount S-1B has hour meter, stop-start switch with run light and preheat switch.
• Expandable to six panels up to 110 feet from the set.
• 20 foot (6m) plug-in panel harness lets you mount your panel anywhere onboard. Better than inaccessible unit mount panels that are prone to vibration problems.
• Low oil pressure, high coolant temp and high exhaust temp safety shutdowns standard.
AC Generator
• Northern Lights, direct coupled, brushless AC generator is maintence free. 4 lead, 1 phase, 50 or 60 Hz output standard. 12 lead, 3 phase optional. Conservative heat rise rating: 95oC/50oC ambient.
• Automatic voltage regulator (AVR) is powered by dedicated AC winding for true 300% short circuit capability and circuit breaker protection. Quick ±1% RMS no load to full load voltage regulation.
• Generator features high quality, Class “H” epoxy insulation, accessible diodes, over-sized bearings and junction box for wiring.
Special Equipment
• Welded steel base frame with drip pan.
• Four plateform mounts isolate vibration.
• White, long-life polyurethane paint.
• Operator’s and parts manuals standard.
Classification Standards
• Consult factory for details.
Marine Diesel M864W3- 25/20 Kw
Engine Block
- Four cycle, 4 cylinder, liquid cooled, naturally aspirated, overhead valve diesel.
- Induction hardened crankshaft. Forged carbon steel – stronger than cast iron.
- Helical cut and ground, carbon steel timing and PTO gears reduce noise.
- Cross flow head for efficient breathing. Glow plugs for quick cold starting.
Cooling System
- Freshwater cooling system in heat exchanger or keel cooled configuration.
- Large, easy-fill single-piece exhaust manifold is freshwater cooled for safety. No hot, dry risers. Fewer troublesome hoses and gaskets. Cast iron to resist corrosion and electrolysis.
- Zinc anode electrolysis protection.
- Heat exchanger cooling is standard. Cupro-nickel tube-type heat exchanger has removable ends for easy cleaning. Rubber impeller seawater pump of bronze and stainless steel is gear driven; no belt.
Fuel System
- Fuel system is self-venting.
- Bosch-type in-line injection pump with 5% mechanical governor for close AC frequency control.
- Pintle injectors with replaceable tips.
- Mechanical lift pump with hand primer. No electric pump to fail.
- Large spin-on fuel filter.
- Flexible fuel lines routed to base.
- Stop solenoid controls the fuel rack, not the throttle, to eliminate speed variances and linkage problems.
Intake and Exhaust
- Meets US EPA Tier III emission standards at date of manufacture.
- Washable air cleaner in cast intake manifold reduces intake noise.
- Cast iron, wet exhaust elbow for safety.
Lubrication System
- Full flow, spin-on oil filter with bypass.
- 6.9 qt (6.5 ltr) oil capacity for better lubrication. 200 hour oil change intervals.
- Oil drain for quick, clean oil changes.
- Closed crankcase vent system traps oil vapor and keeps engine room clean.
DC Electrical System
- DC system uses reliable relays instead of an unrepairable printed circuit board.
- 12 volt starter motor and battery charging alternator with regulator and belt guard.
- Standard panel: Remote mount S-3C has hour meter, stop-start switch with run light and preheat switch. Gauges for oil pressure, coolant temp and DC voltage. Safety shutdowns for low oil pressure, high coolant temp and high exhaust temp.
- Expandable to six panels up to 110 feet from the set.
- 20 foot (6m) plug-in panel harness lets you mount your panel anywhere onboard.
AC Generator
- Northern Lights, direct coupled, brushless AC generator is maintence free. 4 lead, 1 phase, 50 or 60 Hz output standard. 12 lead, 3 phase optional. Conservative heat rise rating: 95oC/50oC ambient.
- Automatic voltage regulator (AVR) is powered by dedicated AC winding for true 300% short circuit capability and circuit breaker protection. Quick ±1% RMS no load to full load voltage regulation.
- Generator features high quality, Class “H” epoxy insulation, accessible diodes, over-sized bearings and junction box for wiring.
Special Equipment
- Welded steel base frame with drip pan.
- Four plateform mounts isolate vibration.
- White, long-life polyurethane paint.
- Operator’s and parts manuals standard.
Classification Standards
- Consult factory for details.
Marine Generator M944T3: 40 Kw
Engine Block
• Four cycle, 4 cylinder, dry turbocharged, overhead valve diesel.
• Induction hardened crankshaft. Forged carbon steel – stronger than cast iron.
• Helical cut and ground, carbon steel timing and PTO gears reduce noise.
• Cross flow head for efficient breathing.
Cooling System
• Freshwater cooling system in heat exchanger or keel cooled configuration.
• Large single-piece exhaust manifold is freshwater cooled for safety. No hot, dry risers. Fewer troublesome hoses and gaskets. Cast iron to resist corrosion and electrolysis.
• Zinc anode electrolysis protection.
• Heat exchanger cooling is standard. Cupro-nickel tube-type heat exchanger has removable ends for easy cleaning. Rubber impeller seawater pump of bronze and stainless steel is gear driven; no belt.
Fuel System
• Direct injection with glow plugs.
• Bosch-type in-line injection pump with 5% mechanical governor for close AC frequency control.
• Pintle injectors.
• Mechanical lift pump with hand primer. No electric pump to fail.
• Large spin-on fuel filter.
• Flexible fuel lines routed to base.
• Stop solenoid controls the fuel rack, not the throttle, to eliminate speed variances and linkage problems.
Intake and Exhaust
• Meets US EPA Tier III emission standards at date of manufacture.
• Dry turbocharger insulated for safety.
• Washable air cleaner in cast intake manifold reduces intake noise.
• Wet exhaust elbow for safety.
Lubrication System
• Full flow, spin-on oil filter with bypass.
• 10.5 qt (10.0 ltr) center well oil pan. 250 hour oil change intervals.
• Oil drain for quick, clean oil changes.
DC Electrical System
• DC system uses reliable relays instead of an unrepairable printed circuit board.
• 12 volt starter motor and battery charging alternator with regulator and belt guard.
• Standard panel: Remote mount S-3C has hour meter, stop-start switch with run light and preheat switch. Gauges for oil pressure, coolant temp and DC voltage. Safety shutdowns for low oil pressure, high coolant temp and high exhaust temp.
• Expandable to six panels up to 110 feet from the set.
• 20 foot (6m) plug-in panel harness lets you mount your panel anywhere onboard.
AC Generator
• Northern Lights, direct coupled, brushless AC generator is maintence free. 12 wire 60 Hz output standard. Conservative heat rise rating: 95oCS/50oC ambient.
• Automatic voltage regulator (AVR) is powered by dedicated AC winding for true 300% short circuit capability and circuit breaker protection. Quick ±1% RMS no load to full load voltage regulation.
• Generator features high quality, Class “H” epoxy insulation, accessible diodes, over-sized bearings and junction box for wiring.
Special Equipment
• Welded steel base frame with drip pan.
• Four plateform mounts isolate vibration.
• Belt guard protects operator.
• White, long-life polyurethane paint.
• Operator’s and parts manuals standard.
Classification Standards
• Consult factory for details.